Calculation of hydrotransport parameters during the inwashing of tailing pits

User Rating:  / 1
PoorBest 
Category: Physical processes
Last Updated on Saturday, 05 January 2013 16:05
Published on Saturday, 05 January 2013 16:05
Hits: 4375

 

Authors: V.B. Bobrov, A.V. Georgieva, V.G. Skosyrev
 
The mode of distributed inwashing of tailing pits is in common use at iron-ore mining and processing enterprises of Krivoi Rog basin. Using of this mode means that a pulp from main pipeline built along the dam is fed to the tailing pit through uniformly disposed outlets. The article offers a new procedure of calculation of overcritical running regimes of complexes of cleaning rejects storing, which for the first time takes into account the number, diameter and length of outlets as well as distance between them. The calculation procedure is meant for determination of metering-head characteristics of systems of cleaning rejects storing and allows determining velocity of slurry flow running through each of outlets.
Files:
2010_11-12 Bob
Date 2012-12-14 Filesize 312.48 KB Download 1353
Tags: hydrotransporttailing pitpulppipelineoutletdischargepressurecritical velocity